Home Tubes Asylum

Questions about tubes and gear that glows. FAQ

Re: vt100mk11 meltdown "need advice"

64.111.33.153


Dear Gary: You didn't state if one of your KT88 was running with a "cherry red "plate; this might be a blown bias feed resistor or grid resistor. Since the amp continued to run, it might be a blown screen resistor to one KT88; this would "shut-off" plate current to THAT tube. (That tube might have had a momentary short) I have a pair of Genelex/MOV KT88's that I have had since high-school, with over 3000 to 5000 hours on 'em, and they still run fine. I think you had just one bad tube; the amp needs to be checked out, however. Please let me know how it turns out. Happy Holidays!!! Joe, aka, the Beam Tube"


This post is made possible by the generous support of people like you and our sponsors:
  VH Audio  


Follow Ups Full Thread
Follow Ups
  • Re: vt100mk11 meltdown "need advice" - Beam Tube 14:32:21 12/20/00 (0)


You can not post to an archived thread.