In Reply to: RE: TFA-204 300B Operating Points posted by jdrouin on March 10, 2017 at 12:39:17
3K is not the series resistance of the primary. 3K is the OPT's primary AC impedance. What you need to input, is the transformer's primary DCR which you can just measure with a DVM. That value should be anywhere from 150 to 300 Ohms as is typical for most transformers. If the primary's DCR is say 200 Ohms, there will be a drop across it of: 200R x 0.06A = 12V. You will be going from 250V down to 238V at the tube's plate.
Edits: 03/12/17Follow Ups:
Thanks. I don't have the OPTs yet so I can't measure. I did however find a thread where Mike indicates the DCR for the TFA-204 is 140 ohm. I reposted it somewhere in the nest here, but the link is:
http://www.audioasylum.com/forums/magnequest/messages/4037.html