In Reply to: RE: You will be better off using those chokes as a plate load in a parafeed amp posted by Chip647 on December 01, 2016 at 04:59:55
What about this one?
Follow Ups:
Put C1 as 0.2uf
Put C2 as 50uF
Put C3 as 100uF
You will have to change the transformer voltage to around 250 for the same output voltage.
Compare the current step response and the ripple voltage
The DCR of the chokes is so low that the filter will ring like heck unless the caps are made large.
Tre'
Have Fun and Enjoy the Music
"Still Working the Problem"
Edits: 12/01/16
Trouble with just trying to use parts on hand.
Hello Tre'!
Can I use 600v rating for the C1 (20uf) and 200v rating cap for both C2 (600uf) as well as C3 (1800uf)??
Thanks!