In Reply to: RE: R&R tubes in Transcendent T8-LN posted by LtMandella on January 01, 2020 at 07:35:09
because you DID have something wrong.
Any idea why a blown fuse didn't cause profound problems, apparently since you only found it by checking fuses?
Follow Ups:
also it might be worth noting: visually there was little indication the fuse was blown - it is one of 3 for the amp. No glass discoloration or burn mark. But continuity test showed it was open.
There must be something wrong with me for not having something wrong.
Well kind of depends on your definition of "profound".
There was basically no bass, and even the mids were distorted.
I don't understand electronic theory well enough to know the function of the circuit that was fused. I would have expected one channel to be completely dead.
But it was not.
The amp is a factory built T8-LN from Transcendent Sound. I have the schematic...
There must be something wrong with me for not having something wrong.