In Reply to: RE: Cartridge alignment and tonearm design posted by Tre' on July 7, 2020 at 11:14:49:
A white paper from Shure suggests a degradation of 5dB in channel separation with a 1° error. 1° is a very typical tip mounting tolerance angle (for azimuth and rake). 1° is a typical cantilever skew tolerance (as quoted from Audio Technica).
The effect of the error in bearing offset to set offset angle will depend on the amplitude of a record warp and the arm length combined with the error in arm height with respect to a reference record thickness and whether the individual record thickness is compensated for.
Regards Anthony
"Beauty is Truth, Truth Beauty.." Keats
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- RE: Cartridge alignment and tonearm design - flood2 20:07:06 07/09/20 (0)