In Reply to: Mundorf ECap Direction posted by Duster on February 20, 2021 at 03:18:55:
The outer foil is preferred to be on the neg. term. or ground
to prevent hum problems. You can find out which lead using
the "hum" test, hooked up to an amp or scope.Have many non-polars here with that ridge too. Polar caps,
the ridge is pos. end.
Edits: 02/20/21
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- RE: Mundorf ECap Direction - Coner 10:21:09 02/20/21 (4)
- RE: Mundorf ECap Direction - Lew 13:10:40 02/21/21 (3)
- RE: Mundorf ECap Direction - Story 07:54:16 02/22/21 (1)
- Structure of a "nonpolar" electrolytic capacitor - Lew 09:23:07 03/08/21 (0)