No. the lightbulb should be bypassed ASAP.

Hi.

A lightbulb will act as a series current limiter to the load (the amp) downstream of it. But once the amp warms up, the lightbulb got
to be bypassed ASAP to provide the full voltage supply needed for the load.

Why? A lightbulb tends to consume a MAJOR part of the supply voltage (being in series of the load downstream) when it is lit up due to its pretty high operation resitance.

I am still working on a better solution to half down the 220V AC mains voltage to an 110V rated audio equipment, without using a step-down transformer (a good one without impairing the sound will be hard to find let alone the cost), or a huge piece of series wire-wound resistor which runs hot hot.

I tried serieing lightbulbs of different wattage (hence dfferent operation resistances) but so far I've found the serie lightbulb
eats up to 70% of the mains voltage. No good for testing or running any audio components. Only for limiting starting currents, yes.

For my purpose pf halving down the AC mains voltage, a last resort may be a serie AC capactor upstream of the load. Again, where to get the cap of the right capacitive reactance is another hugh issue.

Let's see.

c-J


This post is made possible by the generous support of people like you and our sponsors:
  The Cable Cooker  


Follow Ups Full Thread
Follow Ups
  • No. the lightbulb should be bypassed ASAP. - cheap-Jack 11:34:47 04/23/07 (0)

FAQ

Post a Message!

Forgot Password?
Moniker (Username):
Password (Optional):
  Remember my Moniker & Password  (What's this?)    Eat Me
E-Mail (Optional):
Subject:
Message:   (Posts are subject to Content Rules)
Optional Link URL:
Optional Link Title:
Optional Image URL:
Upload Image:
E-mail Replies:  Automagically notify you when someone responds.