Tubes Asylum Questions about tubes and gear that glows. FAQ |
|
In Reply to: DCR of small value fuses? posted by bugeyed on April 27, 2022 at 11:54:42:
Eaton's specification for the "Typical DC cold resistance" of a 125mA AGC fuse is 10.825Ω. I just checked one that I purchased from Digikey last month. It measures 11.2Ω using a 4-wire ohmmeter with 25mA flowing. I calibrated the meter against a 10Ω 0.1% resistor before taking the measurement.
Edits: 04/28/22 04/28/22
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- 125mA Fuse - Triode_Kingdom 10:19:47 04/28/22 (1)
- Thank you TK nt - Tre' 10:44:52 04/28/22 (0)