TESTER-TV10D/U
While testing some tubes today I ran into a problem testing a couple 7236 tubes (Cetron, Sylvania). I had the tester set for 6AS7 thinking this was the class of the 7236. Both tube read out at 200-300 on the GM meter, unlike the 5000-5800 for other tubes marked 6AS7G (Min 1800).
Not wanting to damage the tubes stopped seeking clarafaction of the tube class or settings.
Any advice is appreciated.
Thanks
Wil
This post is made possible by the generous support of people like you and our sponsors:
Topic - 7236 tube testing problem, seeking advise - wdctube 22:49:12 07/28/20 (7)
- RE: 7236 tube testing problem, seeking advise - GeorgePope 15:47:55 08/16/20 (0)
- 6AS7 matching variance distinguishes Pass/Fail values - wdctube 10:45:04 08/01/20 (5)
- RE: 6AS7 matching variance distinguishes Pass/Fail values - Tre' 14:30:14 08/11/20 (4)
- RE: 6AS7 matching variance distinguishes Pass/Fail values - wdctube 08:20:04 08/18/20 (0)
- RE: 6AS7 matching variance distinguishes Pass/Fail values - rivervalley817 15:09:25 08/11/20 (2)
- RE: 6AS7 matching variance distinguishes Pass/Fail values - Tre' 15:54:49 08/11/20 (1)
- RE: 6AS7 matching variance distinguishes Pass/Fail values - rivervalley817 19:11:49 08/11/20 (0)