In Reply to: Consequences of an imbalance between the two sides of a 5U4G rectifier posted by Rick R on July 5, 2008 at 13:39:24:
I alway see some imbalance on my emission tester, but not that much. The result will be a bit of 60 Hz ripple on the supply, since one half is dropping more voltage. Best test is the in-circuit voltage - a weak tube will result in low B+. In a low-current circuit,it might still be fine.