Tubes Asylum Questions about tubes and gear that glows. FAQ |
|
In Reply to: Re: Citation II one channel dead! posted by Jim McShane on February 3, 2007 at 14:06:33:
Problem solved. 220 ohms read across resistor R3 and from R3 to pin 1. But reading from resistor to pin9 the resistance was infinite. Assuming poor pin contact, I inserted and reinserted the tube in Socket V1 until the resistance was read at pin 9. For good measure re-soldered all connections to the socket. Thanks for your help. I was quite confused how the resistor was “good†but still had a problem. Always glad to lean something!will get some cleaner and take care of those sockets.
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- Re: Citation II both channels now working thanks! - needhelp 16:17:23 02/03/07 (1)
- Re: Citation II both channels now working thanks! - Jim McShane 18:19:36 02/03/07 (0)