Tubes Asylum Questions about tubes and gear that glows. FAQ |
|
In Reply to: Re: My EH 300B gold grids only lasted a year. What's the life expectancy of the WE 300B. Thanks. (nt) posted by [Badfinger] on January 21, 2005 at 06:48:40:
Hi,> The EH's no longer hold their bias and slowly drop way
> down to 20mA losing their oomph.Sounds like low emission. Could still be a manufacturing issue, but bascially they are "worn out". There are processes that can be used to "regenerate" valves that have lost emission, but they are not for the fainthearted. Somethings to check in the amps, just to be sure, is the heatervoltage. If it's too high it will wear the valves quickly, if it's too low emission will be low.
Ciao T
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- Re: My EH 300B gold grids only lasted a year. What's the life expectancy of the WE 300B. Thanks. (nt) - Thorsten 09:49:53 01/21/05 (0)