In Reply to: Sub (REL strata 5) grounding issue (help!) posted by Apokalypse on April 30, 2007 at 20:38:16:
"I'm having what appears to be an intermittent grounding problem."Make sure U have good continuity with regards to the black wire.
Disconnect the Neutrik connector and with a DVM, ensure U have solid continuity from the connector to the end of the black wire. U can do this by wiggling/moving the wire while U R measuring the continuity.
U could also check to see if the screw terminals inside the Neutriks connector are tight.
Also ensure U have a secure connection where U have the Black wire attached.
Cheers,
~kenster