RE: grounding and isolation

73.229.163.4


[ Follow Ups ] [ Post Followup ] Thread: [ Display  All  Email ] [ Digital Drive ]

This Post Has Been Edited by the Author

In the case of Ethernet ports on networking gear they all have small isolation transformers onboard so the idea of ground isolating Ethernet is kind of a waste. But audiophiles have found ways to mess that up with high-end shielded Ethernet cables with metal RJ45 connectors at each end. These have the cable's outer shield terminated at the metal connector body at both ends of the cable. Perfect scenario for creating ground loops.

The solution - don't use high-end designer Ethernet cables.

There was an example here in Audio Asylum. Inmate switched to cheapie CAT5 patch cord. No more ground loop hum