Tubes Asylum Questions about tubes and gear that glows. FAQ |
|
In Reply to: RE: my bias is running away on one side even with the bias backed all the way off on that side! posted by immatthewj on July 24, 2020 at 10:35:27:
Ah, that's how those input and current source tubes work. If so then I may have surmised incorrectly. Worth a try though.
Good luck!
Jonesy
"I know just enough to get into trouble. But not enough to get out of it."
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - Jonesy 11:03:04 07/24/20 (24)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - immatthewj 11:27:56 07/24/20 (23)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - Jonesy 17:04:11 07/24/20 (22)
- Thank you! And cap questions? - immatthewj 22:03:52 07/25/20 (21)
- RE: Thank you! And cap questions? - Jonesy 23:42:26 07/25/20 (20)
- RE: Thank you! And cap questions? - immatthewj 17:12:33 07/26/20 (19)
- RE: Thank you! And cap questions? - immatthewj 17:24:29 07/26/20 (18)
- RE: Thank you! And cap questions? - immatthewj 17:44:30 07/26/20 (17)
- RE: Thank you! And cap questions? - Jonesy 18:53:48 07/26/20 (16)
- RE: Thank you! And cap questions? - immatthewj 11:04:37 07/27/20 (15)
- RE: Thank you! And cap questions? - Jonesy 11:44:28 07/27/20 (14)
- RE: Thank you! And cap questions? - immatthewj 14:24:26 07/27/20 (13)
- RE: Thank you! And cap questions? - Jonesy 09:33:47 07/28/20 (11)
- RE: Thank you! And cap questions? - immatthewj 11:48:52 07/28/20 (10)
- ... also a reminder bias is set with no signal. It goes up and down once signal applied. (nt) - Jonesy 15:01:40 07/28/20 (8)
- RE: ... also a reminder bias is set with no signal. It goes up and down once signal applied. (nt) - immatthewj 20:25:26 07/28/20 (7)
- RE: ... also a reminder bias is set with no signal. It goes up and down once signal applied. (nt) - Jonesy 21:27:18 07/28/20 (6)
- RE: ... also a reminder bias is set with no signal. It goes up and down once signal applied. (nt) - immatthewj 12:50:31 07/29/20 (5)
- Economic "in circuit" capacitor meter - Jonesy 14:50:59 07/29/20 (4)
- RE: Economic "in circuit" capacitor meter - immatthewj 14:59:45 07/29/20 (3)
- RE: Economic "in circuit" capacitor meter - Jonesy 15:11:12 07/29/20 (2)
- RE: Economic "in circuit" capacitor meter - immatthewj 15:24:56 07/29/20 (1)
- RE: Economic "in circuit" capacitor meter - immatthewj 16:26:12 08/05/20 (0)
- RE: Thank you! And cap questions? - Jonesy 14:44:08 07/28/20 (0)
- RE: Thank you! And cap questions? - Jonesy 14:54:19 07/27/20 (0)