In Reply to: RE: my bias is running away on one side even with the bias backed all the way off on that side! posted by Jonesy on July 23, 2020 at 09:49:22:
Jonesey, after I replied to you, I took the bottom off of my amp & then I called Cary.
"Unfortunately, we no longer provide tech support over the phone." (If not a direct quote, a close paraphrase.) & then she gave me the web site to contact Cary tech support. Which I will do, but . . . .
So I am like some guy who knows how to change his spark plugs & oil but really has no concept of the internal combustion engine. Except I do understand the internal combustion engine--it's electronics & digital stuff, etc. that leave me clueless beyond the very basics. I can solder & desolder & I do have a multi-meter that has capacitance measurement as a function. I noted that on each side of the Cary, there are 2 each bronze colored Jensen caps that are 11/2" long & about 1" in diameter labeled "Jensen Audio Signal pure copper foil, silver lead out, paper in oil, 0.22 uF/630 WVDC."
With my meter set to measures capacitance, I ON THE GOOD SIDE I got the following readings: 262.2 & 256.6 .
On the bad side I got: 278.0 & one that will read under 1.0 for a few seconds, & then the reading will disappear & the screen will go blank.
Does this sound like the problem, or just another problem my amp was experiencing?
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - immatthewj 11:07:59 07/23/20 (33)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - Jonesy 13:10:22 07/23/20 (32)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - immatthewj 14:35:10 07/23/20 (31)
- Cary Customer Support - AbeCollins 06:51:56 07/28/20 (1)
- RE: Cary Customer Support - immatthewj 11:45:26 07/28/20 (0)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - Jonesy 17:32:42 07/23/20 (28)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - immatthewj 23:48:12 07/23/20 (27)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - Jonesy 05:46:38 07/24/20 (26)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - immatthewj 10:35:27 07/24/20 (25)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - Jonesy 11:03:04 07/24/20 (24)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - immatthewj 11:27:56 07/24/20 (23)
- RE: my bias is running away on one side even with the bias backed all the way off on that side! - Jonesy 17:04:11 07/24/20 (22)
- Thank you! And cap questions? - immatthewj 22:03:52 07/25/20 (21)
- RE: Thank you! And cap questions? - Jonesy 23:42:26 07/25/20 (20)
- RE: Thank you! And cap questions? - immatthewj 17:12:33 07/26/20 (19)
- RE: Thank you! And cap questions? - immatthewj 17:24:29 07/26/20 (18)
- RE: Thank you! And cap questions? - immatthewj 17:44:30 07/26/20 (17)
- RE: Thank you! And cap questions? - Jonesy 18:53:48 07/26/20 (16)
- RE: Thank you! And cap questions? - immatthewj 11:04:37 07/27/20 (15)
- RE: Thank you! And cap questions? - Jonesy 11:44:28 07/27/20 (14)
- RE: Thank you! And cap questions? - immatthewj 14:24:26 07/27/20 (13)
- RE: Thank you! And cap questions? - Jonesy 09:33:47 07/28/20 (11)
- RE: Thank you! And cap questions? - immatthewj 11:48:52 07/28/20 (10)
- ... also a reminder bias is set with no signal. It goes up and down once signal applied. (nt) - Jonesy 15:01:40 07/28/20 (8)
- RE: ... also a reminder bias is set with no signal. It goes up and down once signal applied. (nt) - immatthewj 20:25:26 07/28/20 (7)
- RE: ... also a reminder bias is set with no signal. It goes up and down once signal applied. (nt) - Jonesy 21:27:18 07/28/20 (6)
- RE: ... also a reminder bias is set with no signal. It goes up and down once signal applied. (nt) - immatthewj 12:50:31 07/29/20 (5)
- Economic "in circuit" capacitor meter - Jonesy 14:50:59 07/29/20 (4)
- RE: Economic "in circuit" capacitor meter - immatthewj 14:59:45 07/29/20 (3)
- RE: Economic "in circuit" capacitor meter - Jonesy 15:11:12 07/29/20 (2)
- RE: Economic "in circuit" capacitor meter - immatthewj 15:24:56 07/29/20 (1)
- RE: Economic "in circuit" capacitor meter - immatthewj 16:26:12 08/05/20 (0)
- RE: Thank you! And cap questions? - Jonesy 14:44:08 07/28/20 (0)
- RE: Thank you! And cap questions? - Jonesy 14:54:19 07/27/20 (0)