In Reply to: RE: Dedicated line to Stereo and Switch? posted by Pyfite on July 06, 2016 at 08:08:37
Depending on the distance from Breaker Panel to outlets, and assuming a 20A breaker - either 12- short, 10 medium- up to 100' or 8 gauge for Long - over 200' - if the breaker goes up in amperage raise the gauge...
As for a switch- do NOT use a wall light switch - if you want to have a switch for total power on/off- get a DPDT (Double Pole/Double Throw) switch that is rated above the breaker size and have it switch both the Hot/line and neutral.
Have fun
Happy Listening
Follow Ups:
6bq5, Why would one want the switch to be used on both hot and neutral? If used only on the hot it would sound better in theory. Tweaker
The switth is a silly idea and can only degrade. The op said its for convenience. Come on! Tell him to buy a clapper.......