Audio Asylum Thread Printer Get a view of an entire thread on one page |
For Sale Ads |
74.47.241.167
In Reply to: RE: Safety cap (Type X) ? posted by Tweaker456 on September 24, 2014 at 12:47:07
@28VAC we can assume its not connected to mains directly but tell us more about the circuit/environment
ET
Follow Ups:
These caps go across the secondaries of the JR digital filter. Wall 120VAC to 28VAC to 120VAC. Thanks, Tweaker
Gotcha and yes I think safety caps are in order and I'm pretty sure John would say so.
ET
So much more choice of caps without having to resort to Type X. Tweaker
Re: Question about Jon Risch's new digital filter
Posted by Jon Risch (B) on October 15, 2001 at 20:23:39
In Reply to: Question about Jon Risch's new digital filter posted by Batman on October 15, 2001 at 19:52:19:
Try different values and see. I would start out with 2 uF and a smaller 0.1 uF bypass, and see what you think. One of the units in use and being experimented with is using a 10 uF cap, bypassed with a 0.22 uF stacked foil low inductance cap.
If the transformer steps down and the second one steps back up, then the caps will only see some fraction of the full AC line voltages, and any transients will be blunted by the transformer inductance. So full X or Y rated caps are not absolutely necessary. How close you want to cut the margin depends on how much the step down and back up is. Too much, and you need gobs of current capacity to retain any amount of wattage capacity, too little step down, and you will need to use full AC line rated caps for safety.
See Steve Eddy's post:
http://www.AudioAsylum.com/audio/tweaks/messages/44145.html
the second diagram may be what you seek.
Jon Risch