In Reply to: RE: max voltage for DN2540 CCS posted by DMY on June 30, 2009 at 21:49:27
"What is the max operating voltage for DN2540N5 "
400V
"Is it safe to use it as plate load on 750v B+ ?"
What do you think?
Use the 900V IXYS parts.
.
I don't see any sensible way to assure that the voltage divides equally across each device.
I would order the correct part.
IXYS make depletion mode parts up to 1KV and 400W.
thanks