In Reply to: RE: Pardon the dumb question posted by FenderLover on June 24, 2015 at 07:27:12
No, the DC value will drop in accordance with the choke's DCR. Inductance won't affect it.
--------------------------
Buy Chinese. Bury freedom.
Follow Ups:
after all, different gauges would yield different results for the same henry even though the inductance remains the same.
I like using inductors as I find the sound is more liquid, dynamics are improved because as the field collapse you don't get the momentary sag and you are getting the benefit of the filtering.
iBasso DX100,DX50 DX90. Chord Hugo. HiFiman 901 balanced. RSA Intruder, The Lightning. Fostex TH900 balanced, Hifiman HE-6, 560, 500, JH13 Pro balanced. Lyr2, Audeze. All phones balanced mostly with Whiplash cables. Photo gallery: www.pbase.com/jamato8