In Reply to: RE: Power Transformer Rating posted by Tre' on May 20, 2016 at 08:40:32
Actually, I do believe you'll get the voltages quoted assuming FW/CT, cap input filter and ignore rectifier and other losses. (650/2)*1.414~460. He combined steps in the basic math.
Follow Ups:
"He combined steps in the basic math."
I see that now.
But it's a choke input filter.
BTW I fixed my math.
Half of the end to end voltage times .9, minus losses.
Tre'
Have Fun and Enjoy the Music
"Still Working the Problem"
I believe the OP specified a choke input PS. 325Vrms times 0.9 equals about 290Vdc. Add the losses in the second choke and you are close to 260V. My question is: If you are using CCS fed shunt reg. why the second LC filter?
"It is better to remain silent and thought a fool, then speak and remove all doubt." A. Lincoln
L input, I see that now. That's why I state my assumptions...even if I'm wrong.