In Reply to: RE: I think i found the problem posted by Triode_Kingdom on April 18, 2016 at 16:31:16
You were right, it was the pot. I changed out the caps and there was no change so I decided to remove the bias adjustment pot and it measures bad. So, next thing it trying to find a replacement. Thanx TK.
Follow Ups:
If you don't find a replacement pot at the usual sources like Mouser, Digikey, etc., also try Surplus Sales of Nebraska. They have a lot of unusual items that can't be found anywhere else.
--------------------------
Buy Chinese. Bury freedom.
I went with a linear 25k pot by Allen Bradley. It seems to work great. A setting of -150 is about 3/4 travel. An according to the front amp meter is about 100ma of plate current. Is that a good operating point for just above 1000v on the anode?
1KV @ 100 ma - you're at the maximum plate dissipation rating of the tube. That's too much. I wouldn't run it past 80W, or 80 mA if anode voltage is exactly 1KV. Some people would probably consider 70W the limit for good tube life.
--------------------------
Buy Chinese. Bury freedom.
How does one calculate the dissipation for this amp with fixed bias? regards, Dak
Plate dissipation in watts is plate to cathode voltage times current.