Audio Asylum Thread Printer Get a view of an entire thread on one page |
For Sale Ads |
146.18.173.101
In Reply to: RE: One of these things is not like the other posted by vinnie2 on April 18, 2016 at 13:37:49
They are like the heating element in your electric oven. The radiant heat will kill, not just ambient hot air. Try 105C rated caps as well for longer life.
Follow Ups:
Thing is, if that amplifier is working at the shown operating point, the resistor should only be dissipating 1.5W. (41Vx0.036A), which shouldn't kill the capacitor right away even mounted like that.
Definitely something weird is going on here, I wonder if the B+ is way high
I have been checking voltages back and forth between the different sections and I am not happy with the amount of variance I seem to be getting. Need to search some more.
Some variation is normal but shouldn't be drastic. Begin by drawing a really accurate schematic, make a photocopy for the second channel and then record the DC voltage to ground at each of the tube terminals, the power supply points, etc. It can really help to zoom in on a Problem. One possibility is that those silver mica caps leak, causing the 45 on that side to conduct way too much and then putting a big voltage across the tube's bias reaistor and frying the capacitor. Some voltage checks with a digital multi meter or vacuum tube volt meter will get it all sorted out. The grid oh the 45 should be 0VDC.