In Reply to: RE: HELP: how do I connect a Tamura F-475? posted by pastito on October 21, 2015 at 13:48:21
There's two separate primary windings.
Look at the schematic here:
http://noguchi-trans.co.jp/digitalcatalog/main/tamura.pdf
it shows it all.
Follow Ups:
This is great info. Thank you! Now it is clear. I will use B and P only!
Looking at this picture it looks like a push pull transformer.
Are the markings the same for the PP and the SE transformers but only one set (B-SG-P) internally connected for the SE transformers?
Tre'
Have Fun and Enjoy the Music
"Still Working the Problem"
That is correct. It is a transformer for SE. It is way too small for Push Pull anyway.