The secondary of the power transformer is 600-0.
Current requirement is ~250 ma.
Thanks for any input.
Follow Ups:
What's the topology of the amp?Soft start is up to you. With 12.5 as C1, the inrush is low and probably not experience reactive loading.
I would, at the very least put some NTC thermistors in there. Especially for the heater supply.
Edits: 09/20/14
What is the rest of your filter?
The first cap into a small choke with 500 uf after it is different than using a big choke and 40uf. Sim it in PSUII and it will show you the inrush.
12.5 uf -4H- 12.5uf -4H- 12.5uf .
a
I would definitely use a soft start or in rush limiters...The other option would be to use a GZ34 or a pair of them as they slowly bring up the B+ being they are indirectly heated.