Welcome! Need support, you got it. Or share you ideas and experiences.
71.222.165.182
In Reply to: RE: 15A High Current UO blowing fuses after hard transient hit. posted by PaulMC on June 29, 2009 at 05:18:14
Thanks Paul. I've already purchased 6 1.5KE36CA TVSD's and will replace
them all and go from there.
I just found it odd that 5 of the 6 TVSD's were shorted with D3, which is in the middle of the series connected components, still good but I've seen stranger things in electronics.
Thanks again,
~kenster
Nice. Well done!
Replaced all 6 TVSD's and we are back in business.
Cheers,
~kenster