Audio Asylum Thread Printer Get a view of an entire thread on one page |
For Sale Ads |
178.222.126.156
In Reply to: RE: NYAL OTL 3 posted by v_n_naidu@hotmail.com on June 05, 2012 at 04:30:13
If only one of upper bank three power tubes glows than check the value of G1 grid stop resistor on that glowing tube first , since that grid stop resistors is only non common element of upper power tubes bank negative bias network , but is separate for each power tube , check for bad solder points around that glowing tube socket to .
BTW , NYAL OTL 3 is not very complex electronic unit and some factory service manual which include voltage and current chart , adjusting points ,... etc , well be very helpful for quick service and quick malfunction diagnose .Best Regards !
__
Enlightened Evolution-Astral Projection
Edits: 06/05/12Follow Ups:
Thanks for your comments Banat,
Checked all the resistors when I received the amps and they were all within specs. The problem is not with a particular tube position in the upper bank.
Only 2 of the original tubes in the upper bank do not glow in any position in the upper bank. One tube in the upper bank glows in all the 3 positions in the upper bank. Also all the 3 tubes from the lower bank glow in all the 3 positions in the upper bank. All the six tubes do not glow in the lower bank.
Also all the 10 tubes that were purchased subsequently glow in all the 3 positions in the upper bank. Frankly I'm puzzled. If the problem is with a particular tube position in the upper bank,then it would be easier to find a solution.
This is the reason why I am considering using the amp with 2 tubes in each bank if this does not require any change to the circuit.
Rgds,
Nara
How much plate current are you drawing? Lift the positive leg of the bridge rectifier and insert a meter, if you are over 500ma dial it back to around 350, sounds like you are running them too hard and the ones that do not glow can withstand the high current and the glowing tubes cannot.
Buy a set of tubes from Roger Modjeski, (ram tubes) they are the best you can get.
Hi 714rhino,
Thanks for your reply. To date it appears to be the most appropriate solution to the problem with the OTL3.
Would like to check with you, instead of lifting the positive leg of the bridge rectifier to measure current, could I set the current (350mA) and center balance by adjusting R16 and R23 as indicated in para 9 of the biasing instructions.
Thanks & Rgds,
Nara
Sorry not to get back with you sooner, I will send the alignment procedure to your e-mail tomorrow.
Thanks 714rhino but I do have a copy of the instructions. I am not up to it to bias the amp and would be getting a tech competent friend to do it for me soon. I was just wondering if in the meantime I could just set Ip and balance as indicated in para 9 of the instructions and see if the glowing stops.
Rgds,
Nara
Do the full alignment procedure as described in your manual, if you cannot get the amp to align properly you know that there is a problem either with the tubes or a passive component causing a problem, cap/res...etc.