92.2.95.236
The /PP transformers are gapped for about 5mA of net current when the primaries are in series>>
Kevin wrote this in one post. Can we take it that all the PP interstages are gapped for 5ma? I have a few, like 1621, 1635, 1689, 1660. and would like to use them for a 26 at 5mA.
andy
Follow Ups:
Here are the gaps expressed in mA for each of the ones you mention that correspond to the data sheet performance parameters for the PP version. " < <" means much less than 5mA. "~" means approximately
LL1621 < <5mA
LL1635 < <5mA
LL1660 ~5mA
LL1689 ~5mA
Kevin Carter
K&K Audio
www.kandkaudio.com
Hello,
Great question.
I have a set of LL1660/PP. What is the max. DC can these ITs handle before..?
Regards,
David
The data sheet says that the max current through any single section is 50mA.
Kevin Carter
K&K Audio
www.kandkaudio.com