In Reply to: RE: Resistance values on Extended Foreplay posted by mt1962 on June 29, 2009 at 09:55:59
"Terminals 12 and 21 are at 40K Ohms vs manual @ 83K"
Terminal 12 doesn't worry me much, nor does 21. I think your meter is just picking up the capacitors across these terminals. This would also explain terminal 32 reading differently. If you get a reading of something under 10,000 ohms, then I would be worried.
"Terminal 32 at 54K Ohm vs manual @ 150K"
See above.
"Terminal 31 at 1.1M Ohm vs manual at Infinity
Termina1 15 at 9M Ohm vs manual at Infinity
Terminals 6&7 on the power transformer @ 740 K Ohm vs Infinity in manual
Terminals 9&10 at 15M Ohm vs infinity"
Your meter goes way, way up. These are essentially infinity.
Fire it up and let us know!