Tweakers' Asylum Tweaks for systems, rooms and Do It Yourself (DIY) help. FAQ. |
|
In Reply to: Tripplite Isolator mechanical noise posted by floydandrews on January 1, 2016 at 16:44:12:
It's ironic that a device intended to reduce electrical noise can of itself produce a level of mechanical noise. The cause of the buzz is due to a magnetic property called magnetostriction, which is natural and not caused by a defective product. Positioning the isolation transformer behind the rack or elsewhere that blocks the mechanical sound may be beneficial. A simple vibration control device placed on top of the enclosure can substantially reduce the buzzing sound. However, I once used an isolation transformer in a small room that enhanced the volume of the mechanical buzzing sound, and had to resort to an extreme if not unsafe method of vibration control by positioning a half gallon plastic jug filled with water on top of the isolation transformer enclosure before the sound was dampened enough to be barely audible. That solution seemed too unsafe in theory if not practice, so I discontinued its use. Another isolation transformer application only required a single Eichmann Topper aluminum resonance dampening device placed on top of the enclosure to eliminate a low-level buzzing sound.
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- RE: Tripplite Isolator mechanical noise - Duster 13:18:11 01/02/16 (3)
- magnetostriction - fmak 22:00:31 01/02/16 (2)
- RE: magnetostriction - jhrlrd 15:34:56 01/04/16 (1)
- RE: magnetostriction - aupiho 12:54:41 01/09/16 (0)