In Reply to: RE: New sensor mullard kt88's posted by SETdude on June 16, 2014 at 11:53:35:
"I wasn't implying he did as good a job matching as you do."
What I was driving at was that the "matched" sets from NS are often far enough mismatched that it could cause problems for the end-user. A 15 ma mismatch - unless correctable with individual bias adjustment for each tube - and 450 plate volts would cause the "hottest" tube to have to dissipate almost 7 watts more heat than a tube 15 ma. cooler biasing. That's no small matter, at least IMHO.
This post is made possible by the generous support of people like you and our sponsors:
Follow Ups
- RE: New sensor mullard kt88's - Jim McShane 12:27:44 06/16/14 (4)
- RE: New sensor mullard kt88's - SETdude 11:02:09 06/20/14 (1)
- RE: New sensor mullard kt88's - Jim McShane 14:43:01 06/20/14 (0)
- RE: New sensor mullard kt88's - SETdude 02:07:44 06/18/14 (0)
- I took it that is what you were getting at. . - John PA 12:32:35 06/17/14 (0)