Home Tubes Asylum

Questions about tubes and gear that glows. FAQ

Re: Slow start/soft start

Use a CL70 thermistor (inrush limiter) in series instead of a resistor. The CL70 is rated at 16 Ohms @ 4 amps cold resistance, and the resistance will drop to about 1 Ohm in fifteen seconds or less.

The perfect soft-start for your amp, and only costs $1.39, and is available at www.mouser.com (stock #527-CL70).

Regards,

Mike


This post is made possible by the generous support of people like you and our sponsors:
  Sonic Craft  